Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
2.
Rev. bras. cir. cardiovasc ; 36(6): 817-821, Nov.-Dec. 2021. tab, graf
Article in English | LILACS | ID: biblio-1351676

ABSTRACT

Abstract The coarctation of the aorta is a relatively highly prevalent congenital heart disease and may be diagnosed as an underline cause of hypertension in adolescents and adults. The gold standard treatment for coarctation of the aorta in these patients is being replaced - from open surgery to endovascular therapy. Some prostheses have been developed to treat the coarctation with less acute and chronic complications. The Dominus® Coarctation Aorta (Braile Biomédica) is the first self-expandable prosthesis created specifically to treat coarctation of the aorta, reducing possible acute complications, like aortic rupture or aortic dissection. Here, we discuss the step-by-step method for using this prosthesis.


Subject(s)
Humans , Adolescent , Adult , Aortic Coarctation/surgery , Aortic Coarctation/complications , Aortic Coarctation/diagnostic imaging , Aortic Dissection/complications , Aorta/surgery , Blood Vessel Prosthesis/adverse effects , Stents/adverse effects , Treatment Outcome
3.
Braz. j. infect. dis ; 24(4): 343-348, Jul.-Aug. 2020. tab, graf
Article in English | LILACS, ColecionaSUS | ID: biblio-1132463

ABSTRACT

Abstract Objectives Differential diagnosis of COVID-19 includes a broad range of conditions. Prioritizing containment efforts, protective personal equipment and testing can be challenging. Our aim was to develop a tool to identify patients with higher probability of COVID-19 diagnosis at admission. Methods This cross-sectional study analyzed data from 100 patients admitted with suspected COVID-19. Predictive models of COVID-19 diagnosis were performed based on radiology, clinical and laboratory findings; bootstrapping was performed in order to account for overfitting. Results A total of 29% of patients tested positive for SARS-CoV-2. Variables associated with COVID-19 diagnosis in multivariate analysis were leukocyte count ≤7.7 × 103 mm-3, LDH >273 U/L, and chest radiographic abnormality. A predictive score was built for COVID-19 diagnosis, with an area under ROC curve of 0.847 (95% CI 0.77-0.92), 96% sensitivity and 73.5% specificity. After bootstrapping, the corrected AUC for this model was 0.827 (95% CI 0.75-0.90). Conclusions Considering unavailability of RT-PCR at some centers, as well as its questionable early sensitivity, other tools might be used in order to identify patients who should be prioritized for testing, re-testing and admission to isolated wards. We propose a predictive score that can be easily applied in clinical practice. This score is yet to be validated in larger populations.


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Pneumonia, Viral/diagnosis , Coronavirus Infections/diagnosis , Clinical Laboratory Techniques , Radiography, Thoracic , Cross-Sectional Studies , Predictive Value of Tests , Sensitivity and Specificity , Pandemics , Betacoronavirus , COVID-19 Testing , SARS-CoV-2 , COVID-19
4.
Rev. bras. cir. cardiovasc ; 33(3): 286-290, May-June 2018. tab
Article in English | LILACS | ID: biblio-958417

ABSTRACT

Abstract Objective: Rhythm abnormalities following transcatheter aortic valve implantation (TAVI) and indications for permanent pacemaker implantation (PPI) were reviewed, which aren't well established in the current guidelines. New left bundle branch block and atrioventricular block are the most common electrocardiographic changes after TAVI. PPI incidence ranges from 9-42% for self-expandable and 2.5-11.5% for balloon expandable devices. Not only anatomical variations in conduction system have an important role in conduction disorders, but different valve characteristics and their relationship with cardiac structures as well. Previous right bundle branch block has been confirmed as one of the most significant predictors for PPI.


Subject(s)
Humans , Pacemaker, Artificial , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/therapy , Transcatheter Aortic Valve Replacement/adverse effects , Cardiac Pacing, Artificial/methods , Risk Factors , Treatment Outcome
5.
Rev. bras. cir. cardiovasc ; 32(1): 43-48, Jan.-Feb. 2017. tab
Article in English | LILACS | ID: biblio-843462

ABSTRACT

Abstract Objective: To evaluate our experience following the introduction of a percutaneous program for endovascular treatment of aortic diseases using Perclose Proglide® assessing efficacy, complications and identification of potential risk factors that could predict failure or major access site complications. Methods: A retrospective cohort study during a two-year period was performed. All the patients submitted to totally percutaneous endovascular repair (PEVAR) of aortic diseases and transcatheter aortic valve implantation since we started the total percutaneous approach with the preclosure technique from November 2013 to December 2015 were included in the study. The primary endpoint was major ipsilateral access complication, defined according to PEVAR trial. Results: In a cohort of 123 patients, immediate technical success was obtained in 121 (98.37%) patients, with only two (0.82%) cases in 242 vascular access sites that required intervention immediately after the procedure. Pairwise comparisons revealed increased major access complication among patients with >50% common femoral artery (CFA) calcification vs. none (P=0.004) and > 50% CFA calcification vs. < 50% CFA calcification (P=0.002). Small artery diameter (<6.5 mm) also increased major access complication compared to bigger diameters (> 6.5 mm) (P=0.027). Conclusion: The preclosure technique with two Perclose Proglide® for PEVAR is safe and effective. Complications occur more often in patients with unfavorable access site anatomy and the success rate can be improved with proper patient selection.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Suture Techniques/instrumentation , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Abdominal/surgery , Endovascular Procedures/methods , Retrospective Studies , Risk Factors , Treatment Outcome , Femoral Artery
SELECTION OF CITATIONS
SEARCH DETAIL